18-3000kVA

EB Series

The EB series diesel genset offers a reliable, clean, and fuel-efficient power solution for diverse application scenarios. Featuring high-quality Baudouin engines and Leroy Somer generators, it ensures dependable operation and efficiency across a power range of 18 kVA to 3000 kVA.

Ideal for both continuous and backup power needs, the EB series is designed to meet varying energy demands with stability and cost-effectiveness.

EB Series
EB Series
EB Series
Commited to Service

Dual Certification
Dual certification for stage II & III

Commited to Service

Portable Design
Easy to transport, quick Installation

Commited to Service

Easy Operation
Simple operation with plug-and-play

Commited to Service

Powerful Output
Reliable power output in tough conditions

Features

Intuitive Operation

Plug and Play Function, Rapid Start-Up &  Excellent Load Surge

 

Eco-Friendly & Low-Carbon

Meets Stage II & Stage III Emission Standards

Durable, Safe & Dependable

Features high-pressure common rail fuel injection and turbocharging with a maximum pressure ratio of 2200bar

Ask an Expert

PowerLink PES battery storage systems provide tailored, high-efficiency energy solutions for sustainable power around the world.

EB Series Parameter

B45S
B65S
B80S
B100S
B135S
B150S
B200S
B250S
B320S
B400S
B450S
B500S
B650S
B800S
B900S
B1000S
B1250S
B45S

B45S

Engine Model 4M06G50/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 45 kVA / 36 kW \ \ \
ESP 50 kVA / 40 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B65S

B65S

Engine Model 4M10G70/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 65 kVA / 52 kW \ \ \
ESP 72 kVA / 57 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B80S

B80S

Engine Model 4M10G88/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 80 kVA / 64 kW \ \ \
ESP 88 kVA / 70 kW \ \ \

 

Specification

ATS Manual

Warranty Manual

Brochure Manual

B100S

B100S

Engine Model 4M10G110/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 100 kVA / 80 kW \ \ \
ESP 110 kVA / 88 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B135S

B135S

Engine Model 6M11G150/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 135 kVA / 108 kW \ \ \
ESP 150 kVA / 120 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B150S

B150S

Engine Model 6M11G165/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 150 kVA / 120 kW \ \ \
ESP 165 kVA / 132 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B200S

B200S

Engine Model 6M16G220/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 200 kVA / 160 kW \ \ \
ESP 220 kVA / 176 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B250S

B250S

Engine Model 6M16G275/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 250 kVA / 200 kW \ \ \
ESP 275 kVA / 220 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B320S

B320S

Engine Model 6M16G350/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 320 kVA / 256 kW \ \ \
ESP 250 kVA / 280 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B400S

B400S

Engine Model 6M21G440/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 400 kVA / 320 kW \ \ \
ESP 440 kVA / 352 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B450S

B450S

Engine Model 6M21G550/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 450 kVA / 360 kW \ \ \
ESP 500 kVA / 400 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B500S

B500S

Engine Model 6M21G550/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 500 kVA / 400 kW \ \ \
ESP 550 kVA / 440 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B650S

B650S

Engine Model 6M33G715/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 650 kVA / 520 kW \ \ \
ESP 715 kVA / 572 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B800S

B800S

Engine Model 12M26G900/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 800 kVA / 640 kW \ \ \
ESP 880 kVA / 704 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B900S

B900S

Engine Model 12M26G1000/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 900 kVA / 720 kW \ \ \
ESP 990 kVA / 792 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B1000S

B1000S

Engine Model 12M26G1100/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 1000 kVA / 800 kW \ \ \
ESP 1100 kVA / 880 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

B1250S

B1250S

Engine Model 12M33G1400/5 \ \ \
Engine Brand Baudouin \ \ \
Voltage 380V 400V 415V 440V
PRP 125 kVA / 1000 kW \ \ \
ESP 1375 kVA / 1100 kW \ \ \

Specification

ATS Manual

Warranty Manual

Brochure Manual

Video

EB Series video

  • Mining
  • Construction
  • Data Center
  • Prime power
Mining

Mining

PowerLink Mining Power Solutions deliver rugged, reliable energy for one of the world’s toughest industries. From remote exploration camps to full-scale mining operations, our EB generator sets provide continuous electricity to power drilling, extraction, processing, and worker facilities.

Learn More
Construction

Construction

PowerLink provides reliable and flexible power solutions designed for the demanding needs of construction sites. Whether for road and bridge projects, urban developments, or remote worksites, our generator sets deliver rugged performance, fuel efficiency, and dependable electricity to keep your operations running smoothly.

Learn More
Data Center

Data Center

PowerLink data center generators deliver reliable backup power for mission-critical facilities. With advanced engines and fast-start capability, they minimize downtime and keep operations running—whether for hyperscale, colocation, or enterprise data centers.

Learn More
Prime power

Prime power

PowerLink Prime Power Generators are engineered for applications that demand continuous, reliable electricity without relying on the grid. Built with robust engines and advanced control systems, they provide a stable and dependable power source for industries operating in remote or off-grid locations.

Learn More

FAQs

What do you need to know when installing a genset?

When installing a genset, the following aspects should be noted:

  • The installation site should have good ventilation, with sufficient air intake at the generator end and good exhaust at the engine end.
  • The surroundings of the installation site should be kept clean, and items that can produce corrosive gases and vapours such as acidic and alkaline substances should be avoided nearby. Fire-fighting equipment should be available where possible.
  • If used indoors, the exhaust pipe must be vented outdoors, and the pipe diameter must be greater than or equal to the exhaust pipe diameter of the muffler. The number of elbows in the connected pipe should not exceed three, to ensure smooth exhaust. The pipe should be inclined downward at 5-10 degrees to prevent rainwater from entering. If the exhaust pipe is vertically installed, a rain cover must be added.
  • When using a concrete foundation, use a spirit level to ensure its levelness during installation, so that the unit is fixed on a level foundation. Special shock-absorbing pads or base bolts should be used between the unit and the foundation.
  • The genset’s outer shell must have a reliable protective ground. For generators that require a neutral point directly grounded, a professional should perform the neutral point grounding and be equipped with lightning protection devices. It is strictly forbidden to use the grounding device of the power grid to directly ground the neutral point.
  • The bidirectional switch between the generator and the power grid must be very reliable to prevent reverse power transmission, this switch must also be tested and approved by the local power department.
  • The wiring for starting the battery must be secure.

How long is the product delivery cycle?

For standard products, from the time the customer places the order until the product is shipped, depending on the power and series, it generally takes 2-6 months.

Precautions before equipment commissioning?

Before commissioning each piece of equipment or project, on-site inspections must be done in advance. You can obtain an inspection checklist from the after-sales department, follow the requirements, and provide videos and photos to the after-sales department.

What happens if I overload the generator?

A genset should not be continuously overloaded after operation (it is recommended to run at full load) but should be in an overloaded state for a very short time, especially during the start-up period. If a genset is operated for a long period of time and is in an overloaded state (i.e., exceeding its maximum rated value), several things can happen.

These include:

  • Overheating of the cooling system.
  • Overheating of the AC generator winding.
  • Low oil pressure due to decreased oil viscosity.
  • Shortening of the generator’s working life.

All engines are designed to operate under different loads, ranging from maximum to minimum. When light loads (minimum load) continue for a long period of time, causing the engine to not be able to recover to a normal operating temperature, which can cause problems within the generator, such as the formation of varnish, which means that the oil normally burned in the cylinder is heated and forms a layer of paint on the cylinder sleeve. If light loads continue, visible blue smoke will appear, and the engine will require maintenance work to clean or replace the liner.

Ultra-low temperature operation of diesel gensets

Diesel generator sets require preheaters such as water jacket preheaters, fuel oil preheaters, battery heaters, and space heaters to operate at ultra-low temperatures (such as below minus 10°C).

All products provided by our company are energy products
Welcome to contact us