WPS2500S

Exclusively tailor-made for data center, the WPS2500S (WPS2250S-AU) is a high-performance container diesel generator engineered to deliver uncompromising reliability for mission-critical power needs. With a rated power of 2000kW and rated capacity of 2500KVA, this unit serves as a robust emergency backup or 24/7 prime power source—with support for multi-unit paralleling to scale capacity, even forming small-scale power stations. Designed to address data centers’ core pain points (uninterrupted operation, noise control, space efficiency, and safety), it adheres to CE and IEC electrical safety standards, ensuring seamless integration into high-stakes power ecosystems. From grid outage protection to continuous load support, the WPS2500S redefines power security, efficiency, and adaptability for modern data centers.
WPS2500S
Commited to Service

Modular structure design

Commited to Service

Genuine spare parts

Commited to Service

Plug-and-Play Convenience

Commited to Service

Rugged & Reliable Performance

Features

Uninterrupted 24/7 Operation

A dual-layer fuel system (2400L main tank + 10600L auxiliary tank) for 24 hours of non-stop runtime

Ultra-Quiet Performance

Features a 100mm thick galvanized steel housing (enhanced sound insulation) and a labyrinth muffler that attenuates mid-to-low frequency noise.

Space-Efficient Design

Maximizes utilization with a 40ft high-cube container design, compatible with 20ft standard containers via twist-lock lugs for mixed stacking

Comprehensive Safety

IP54-rated control cabinet, Grade 4 earthquake resistance

Ask an Expert

PowerLink provides tailored, high-efficiency energy solutions for sustainable power around the world.

Specification

Model: WPS2500S
Frequency: Hz 50
Rotate speed: RPM 1500
Prime power (PRP): kVA / kW 2500 / 1600
Standby power (ESP): kVA / kW 2700 / 1760
Rated voltage: V 415
Noise level: dB@1m 85
Protection class: IP54
Tank capacity: L 2400
Dimensions: mm 12192×2438×2896

 

Download

WPS2500S Specification Datasheet

WPS2500S-Specification Register & Download

WPS2500S Warranty Manual

WPS2500S Warranty Manual Register & Download

WPS2500S Brochure

WPS2500S Brochure Register & Download

FAQs

Can they provide 24-hour uninterrupted power supply?

Yes. Standard large-capacity fuel tanks are available, with support for external tank expansion to easily cover 24-hour operation needs.

How to choose your new power generation equipment?

Many customers need to consider the technical and economic feasibility of diesel power generation solutions. Usually the diesel genset is combined with the external large power grid, and the energy supply complements each other, which can improve the reliability and flexibility of the entire system.

To find a cost-effective, technically reliable and more environmentally friendly power generation solution, we recommend that you consider the following important factors when choosing a power generation equipment:

  • The most important thing is the installation cost. Diesel genset solutions offer very competitive installation costs compared to other power generation systems, with a limited footprint for a single kilowatt project.
  • Power generation efficiency. The power generation efficiency of diesel gensets directly affects the economy of the project. PowerLink diesel gensets are efficient and offer a high value.
  • Manufacturing and commissioning time. PowerLink diesel gensets usually take 3 to 6 months from production time plus construction and commissioning time. Your cash on delivery time will be shorter if you have it in stock.
  • Modular installation solution. Considering that the equipment is ultimately delivered safely to the installation site, the modular structure makes project installation easier and commissioning simpler and faster.
  • Another very important factor in determining the choice of power generation equipment: the operating expenses associated with the equipment. These aspects need to be considered: service intervals, spare parts costs, downtime during maintenance, and the entire working cycle of the equipment before the overhaul. Based on our long experience, we offer multi-year service contracts for PowerLink gensets. This can help reduce the need for spare parts and can predict service times in advance, reducing operating costs throughout the engine’s working life.
  • Help you select the most suitable equipment through the load analysis of the project. PowerLink’s wide range of diesel engines (5 to 3250KVA) will help you find the right solution for you.
  • The surrounding environmental conditions will have an impact on the use of the equipment, thus affecting its actual power output capacity. In other words, in some cases, your power output may be much lower than the rated power. If you plan to operate equipment at high temperatures and/or altitudes significantly above sea level, be aware of this factor.

Where can I buy PowerLink products?

  1. We have dealers in more than 100 countries worldwide, and you can contact local dealers to purchase products. In areas without dealers, you can contact our offices directly, and our sales experts will provide a one-on-one service with you.

What requirements do data centers have for diesel generator sets?

Diesel generator sets for data centers must have a performance grade of Grade G3 or above to ensure the stability of output frequency, voltage and waveform. They should be equipped with automation functions such as automatic start-up, parallel operation, switching and remote monitoring capabilities to reduce manual intervention and improve equipment response speed and reliability. Moreover, they need to be configured with different power types based on actual demands.Emergency Standby Power (ESP) is suitable for data center emergency power supply, requiring that the average output power within 24 hours does not exceed 70% of ESP to ensure sufficient power support in emergencies. Prime Rated Power (PRP) is the main daily operating power, which must meet the daily load requirements of data centers and ensure the stable operation of equipment under normal working conditions. Continuous Operating Power (COP) refers to the long-term stable operating power, which is usually lower than PRP and applicable to scenarios requiring long-term continuous operation.

All products provided by our company are energy products
Welcome to contact us