10-2500kVA
QSV Series
The QSV series diesel generator sets are built with international brand components, featuring engines from PowerLink, Perkins, Kubota, and Cummins. These generators offer high quality, cost-effectiveness, sound insulation, and rain protection. With a power range of 10KVA to 2500KVA, they suffice as dependable primary and standby power supply sources, meeting various application needs with safety and efficiency.
Low Investment
Minimal operating costs
Moveable Design
Easily transportable and quick to install
Simple Control
Easy to operate, Plug and Play
Strong Output
Strong power output in extreme
conditions
Features
Low Initial Investment
Minimal Operating Costs
Intuitive Operation
Plug and Play Functionality
Cost-Efficient:
Low Capital & Operational Expenses
Safe & Reliable Performance
Delivers Strong Performance in Extreme Conditions
Ask an Expert
PowerLink PES battery storage systems provide tailored, high-efficiency energy solutions for sustainable power around the world.
QSV Series Parameter
QSV7KS
| Engine Model | D905-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 7 kVA / 5 kW | \ | \ | \ |
| ESP | 7 kVA / 6 kW | \ | \ | \ |
QSV10KS
| Engine Model | D1105-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 10 kVA / 8 kW | \ | \ | \ |
| ESP | 11 kVA / 9 kW | \ | \ | \ |
QSV15KS
| Engine Model | D1703-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 15 kVA / 12 kW | \ | \ | \ |
| ESP | 17 kVA / 13 kW | \ | \ | \ |
QSV18KS
| Engine Model | D1803-M-DI-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 18 kVA / 14 kW | \ | \ | \ |
| ESP | 19 kVA / 15 kW | \ | \ | \ |
QSV20KS
| Engine Model | V2203-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 20 kVA / 16 kW | \ | \ | \ |
| ESP | 22 kVA / 18 kW | \ | \ | \ |
QSV23KS
| Engine Model | V2403-M-DI-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 23 kVA / 18 kW | \ | \ | \ |
| ESP | 25 kVA / 20 kW | \ | \ | \ |
QSV30KS
| Engine Model | V3300-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 30 kVA / 24 kW | \ | \ | \ |
| ESP | 33 kVA / 26 kW | \ | \ | \ |
QSV37KS
| Engine Model | V3300-T-E2BG2 | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 37 kVA / 30 kW | \ | \ | \ |
| ESP | 41 kVA / 32 kW | \ | \ | \ |
QSV45KS
| Engine Model | V3800DI-T-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 45 kVA / 36 kW | \ | \ | \ |
| ESP | 50 kVA / 40 kW | \ | \ | \ |
SG7KS
| Engine Model | D905-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 7 kVA / 5 kW | \ | \ | \ |
| ESP | 7 kVA / 6 kW | \ | \ | \ |
SG10KS
| Engine Model | D1105-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 10 kVA / 8 kW | \ | \ | \ |
| ESP | 11 kVA / 9 kW | \ | \ | \ |
SG15KS
| Engine Model | D1703-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 15 kVA / 12 kW | \ | \ | \ |
| ESP | 17 kVA / 13 kW | \ | \ | \ |
SG18KS
| Engine Model | D1803-M-DI-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 18 kVA / 14 kW | \ | \ | \ |
| ESP | 19 kVA / 15 kW | \ | \ | \ |
SG20KS
| Engine Model | V2203-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 20 kVA / 16 kW | \ | \ | \ |
| ESP | 22 kVA / 18 kW | \ | \ | \ |
SG23KS
| Engine Model | V2403-M-DI-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 23 kVA / 18 kW | \ | \ | \ |
| ESP | 25 kVA / 20 kW | \ | \ | \ |
SG30KS
| Engine Model | V3300-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 30 kVA / 24 kW | \ | \ | \ |
| ESP | 33 kVA / 26 kW | \ | \ | \ |
SG45KS
| Engine Model | V3800DI-T-BG | \ | \ | \ |
| Engine Brand | KUBOTA | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 45 kVA / 36 kW | \ | \ | \ |
| ESP | 50 kVA / 40 kW | \ | \ | \ |
SG30CS
| Engine Model | 4B3.9-G12 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 30 kVA / 24 kW | \ | \ | \ |
| ESP | 33 kVA / 26 kW | \ | \ | \ |
SG45CS
| Engine Model | 4BT3.9-G1 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 45 kVA / 36 kW | \ | \ | \ |
| ESP | 50 kVA / 40 kW | \ | \ | \ |
SG60CS
| Engine Model | 4BTA3.9-G2 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 220V | 230V | 240V | \ |
| PRP | 60 kVA / 48 kW | \ | \ | \ |
| ESP | 66 kVA / 53 kW | \ | \ | \ |
QSV10PS
| Engine Model | 403D-11G | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 10 kVA / 8 kW | \ | \ | \ |
| ESP | 11 kVA / 9 kW | \ | \ | \ |
QSV13PS
| Engine Model | 403D-15G | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 13 kVA / 10 kW | \ | \ | \ |
| ESP | 15 kVA / 11 kW | \ | \ | \ |
QSV15PS
| Engine Model | 403A-15G2 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 15 kVA / 12 kW | \ | \ | \ |
| ESP | 17 kVA / 13 kW | \ | \ | \ |
QSV20PS
| Engine Model | 404D-22G | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 20 kVA / 16 kW | \ | \ | \ |
| ESP | 22 kVA / 18 kW | \ | \ | \ |
QSV30PS
| Engine Model | 1103A-33G | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 30 kVA / 24 kW | \ | \ | \ |
| ESP | 33 kVA / 26 kW | \ | \ | \ |
QSV45PS
| Engine Model | 1103A-33TG1 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 45 kVA / 36 kW | \ | \ | \ |
| ESP | 50 kVA / 40 kW | \ | \ | \ |
QSV60PS
| Engine Model | 1103A-33TG2 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 60 kVA / 48 kW | \ | \ | \ |
| ESP | 66 kVA / 53 kW | \ | \ | \ |
QSV80PS
| Engine Model | 1104A-44TG2 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 80 kVA / 64 kW | \ | \ | \ |
| ESP | 88 kVA / 70 kW | \ | \ | \ |
QSV100PS
| Engine Model | 1104C-44TAG2 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 100 kVA / 80 kW | \ | \ | \ |
| ESP | 110 kVA / 90 kW | \ | \ | \ |
QSV135PS
| Engine Model | 1106A-70TG1 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 135 kVA / 105 kW | \ | \ | \ |
| ESP | 150 kVA / 120 kW | \ | \ | \ |
QSV150PS
| Engine Model | 1106A-70TAG2 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 150 kVA / 120 kW | \ | \ | \ |
| ESP | 165 kVA / 132 kW | \ | \ | \ |
QSV180PS
| Engine Model | 1106A-70TAG3 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 180 kVA / 144 kW | \ | \ | \ |
| ESP | 200 kVA / 160 kW | \ | \ | \ |
QSV200PS
| Engine Model | 1106A-70TAG4 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 200 kVA / 160 kW | \ | \ | \ |
| ESP | 220 kVA / 176 kW | \ | \ | \ |
QSV250PS
| Engine Model | 1206A-E70TTAG3 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 250 kVA / 200 kW | \ | \ | \ |
| ESP27 | 275 kVA / 220 kW | \ | \ | \ |
QSV300PS
| Engine Model | 1506A-E88TAG5 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 300 kVA / 240 kW | \ | \ | \ |
| ESP | 330 kVA / 264 kW | \ | \ | \ |
QSV400PS
| Engine Model | 2206C-E13TAG3 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 400 kVA / 320 kW | \ | \ | \ |
| ESP | 440 kVA / 352 kW | \ | \ | \ |
QSV450PS
| Engine Model | 2506C-E15TAG1 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 450 kVA / 360 kW | \ | \ | \ |
| ESP | 495 kVA / 396 kW | \ | \ | \ |
QSV500PS
| Engine Model | 2506C-E15TAG2 | \ | \ | \ |
| Engine Brand | Perkins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 500 kVA / 400 kW | \ | \ | \ |
| ESP | 550 kVA / 440 kW | \ | \ | \ |
QSV27CS
| Engine Model | 4B3.9-G1 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 27 kVA / 22 kW | \ | \ | \ |
| ESP | 30 kVA / 24 kW | \ | \ | \ |
QSV30CS
| Engine Model | 4B3.9-G12 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 30 kVA / 24 kW | \ | \ | \ |
| ESP | 33 kVA / 27 kW | \ | \ | \ |
QSV42CS
| Engine Model | 4BT3.9-G1 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 43 kVA / 34 kW | \ | \ | \ |
| ESP | 47 kVA / 38 kW | \ | \ | \ |
QSV60CS
| Engine Model | 4BTA3.9-G2 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 60 kVA / 48 kW | \ | \ | \ |
| ESP | 66 kVA / 53 kW | \ | \ | \ |
QSV80S
| Engine Model | 4BTA3.9-G11 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 80 kVA / 64 kW | \ | \ | \ |
| ESP | 90 kVA / 72 kW | \ | \ | \ |
QSV100CS
| Engine Model | 6BT5.9-G2 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 100 kVA / 80 kW | \ | \ | \ |
| ESP | 110 kVA / 88 kW | \ | \ | \ |
QSV135CS
| Engine Model | 6BTAA5.9-G2 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 135 kVA / 105 kW | \ | \ | \ |
| ESP | 145 kVA / 116 kW | \ | \ | \ |
QSV150CS
| Engine Model | 6BTAA5.9-G12 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 150 kVA / 120 kW | \ | \ | \ |
| ESP | 165 kVA / 132 kW | \ | \ | \ |
QSV180CS
| Engine Model | 6CTA8.3-G1 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 180 kVA / 145 kW | \ | \ | \ |
| ESP | 200 kVA / 160 kW | \ | \ | \ |
QSV180CS
| Engine Model | 6CTA8.3-G2 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 180 kVA / 145 kW | \ | \ | \ |
| ESP | 200 kVA / 160 kW | \ | \ | \ |
QSV200CS
| Engine Model | 6CTAA8.3-G2 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 200 kVA / 160 kW | \ | \ | \ |
| ESP | 220 kVA / 176 kW | \ | \ | \ |
QSV250CS
| Engine Model | 6LTAA8.9-G2 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 250 kVA / 200 kW | \ | \ | \ |
| ESP | 264 kVA / 211 kW | \ | \ | \ |
QSV320CS
| Engine Model | 6LTAA9.5-G1 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 320 kVA / 256 kW | \ | \ | \ |
| ESP | 350 kVA / 280 kW | \ | \ | \ |
QSV380CS
| Engine Model | 6ZTAA13-G3 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 388 kVA / 310 kW | \ | \ | \ |
| ESP | 425 kVA / 340 kW | \ | \ | \ |
QSV440CS
| Engine Model | QSZ13-G2 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 438 kVA / 350 kW | \ | \ | \ |
| ESP | 468 kVA / 375 kW | \ | \ | \ |
QSV500CS
| Engine Model | QSZ13-G3 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 500 kVA / 400 kW | \ | \ | \ |
| ESP | 550 kVA / 440 kW | \ | \ | \ |
QSV650CS
| Engine Model | KTA19-G8 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 650 kVA / 520 kW | \ | \ | \ |
| ESP | 715 kVA / 572 kW | \ | \ | \ |
QSV650CS
| Engine Model | QSK19-G4 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 650 kVA / 520 kW | \ | \ | \ |
| ESP | 715 kVA / 572 kW | \ | \ | \ |
QSV800CS
| Engine Model | KTA38-G2B | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 800 kVA / 640 kW | \ | \ | \ |
| ESP | 880 kVA / 704 kW | \ | \ | \ |
QSV900CS
| Engine Model | KTA38-G2A | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 900 kVA / 720 kW | \ | \ | \ |
| ESP | 990 kVA / 792 kW | \ | \ | \ |
QSV1000CS
| Engine Model | KTA38-G5 | \ | \ | \ |
| Engine Brand | Cummins | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 1000 kVA / 800 kW | \ | \ | \ |
| ESP | 1100 kVA / 880 kW | \ | \ | \ |
QSV10XS
| Engine Model | VR3-1.4G1 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 10 kVA / 8 kW | \ | \ | \ |
| ESP | 11 kVA / 9 kW | \ | \ | \ |
QSV15XS
| Engine Model | VR4-2.3G1 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 15 kVA / 12 kW | \ | \ | \ |
| ESP | 16 kVA / 13 kW | \ | \ | \ |
QSV20XS
| Engine Model | VR4-2.7G1 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 20 kVA / 16 kW | \ | \ | \ |
| ESP | 22 kVA / 18 kW | \ | \ | \ |
QSV30XS
| Engine Model | VR4-3.2G1 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 30 kVA / 24 kW | \ | \ | \ |
| ESP | 33 kVA / 26 kW | \ | \ | \ |
QSV45XS
| Engine Model | VR4-3.2TG2 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 45 kVA / 36 kW | \ | \ | \ |
| ESP | 50 kVA / 40 kW | \ | \ | \ |
QSV60XS
| Engine Model | VR4-4.1TG2 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 60 kVA / 48 kW | \ | \ | \ |
| ESP | 66 kVA / 53 kW | \ | \ | \ |
QSV70XS
| Engine Model | VR4-4.1TAG2 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 70 kVA / 54 kW | \ | \ | \ |
| ESP | 77 kVA / 59 kW | \ | \ | \ |
QSV80XS
| Engine Model | VR4-4.1TAG3 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 80 kVA / 64 kW | \ | \ | \ |
| ESP | 88 kVA / 70 kW | \ | \ | \ |
QSV110XS
| Engine Model | VR4-4.8TAG2 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 110 kVA / 88 kW | \ | \ | \ |
| ESP | 121 kVA / 97 kW | \ | \ | \ |
QSV125XS
| Engine Model | VR4-4.8TAG3 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 125 kVA / 100 kW | \ | \ | \ |
| ESP | 138 kVA / 100 kW | \ | \ | \ |
QSV165XS
| Engine Model | VR6-6.5TAG2 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 165 kVA / 132 kW | \ | \ | \ |
| ESP | 182 kVA / 145 kW | \ | \ | \ |
QSV200XS
| Engine Model | VR6-9.7TAG1 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 200 kVA / 160 kW | \ | \ | \ |
| ESP | 220 kVA / 176 kW | \ | \ | \ |
QSV250XS
| Engine Model | VR6-10TAG1 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 250 kVA / 200 kW | \ | \ | \ |
| ESP | 275 kVA / 220 kW | \ | \ | \ |
QSV315XS
| Engine Model | VR6-10TAG2 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 315 kVA / 250 kW | \ | \ | \ |
| ESP | 346 kVA / 275 kW | \ | \ | \ |
QSV375XS
| Engine Model | VR6-12TAG2 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 375 kVA / 300 kW | \ | \ | \ |
| ESP | 412 kVA / 330 kW | \ | \ | \ |
QSV450XS
| Engine Model | VR6-13TAG3 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 450 kVA / 360 kW | \ | \ | \ |
| ESP | 495 kVA / 396 kW | \ | \ | \ |
QSV500XS
| Engine Model | VR6-13TAG4 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 500 kVA / 400 kW | \ | \ | \ |
| ESP | 550 kVA / 440 kW | \ | \ | \ |
QSV625XS
| Engine Model | VR6-25TAG4 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 625 kVA / 500 kW | \ | \ | \ |
| ESP | 688 kVA / 550 kW | \ | \ | \ |
QSV800XS
| Engine Model | VR6-25TAG5 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 800 kVA / 640 kW | \ | \ | \ |
| ESP | 880 kVA / 715 kW | \ | \ | \ |
QSV900XS
| Engine Model | VR6-35TAG4 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 900 kVA / 720 kW | \ | \ | \ |
| ESP | 1000 kVA / 800 kW | \ | \ | \ |
QSV1000XS
| Engine Model | VR6-35TAG5 | \ | \ | \ |
| Engine Brand | POWERLINK | \ | \ | \ |
| Voltage | 380V | 400V | 415V | 440V |
| PRP | 1000 kVA / 800 kW | \ | \ | \ |
| ESP | 1100 kVA / 880 kW | \ | \ | \ |
Applications
- Mining
- Port
- Construction
- Back-up Power
Mining
PowerLink offers a variety of products within the QSV Series to meet diverse application needs and installation requirements, ideal for Mining, Port, Construction, Prime power and back-up power
Learn More
Port
PowerLink offers a variety of products within the QSV Series to meet diverse application needs and installation requirements, ideal for Mining, Port, Construction, Prime power and back-up power
Learn More
Construction
PowerLink offers a variety of products within the QSV Series to meet diverse application needs and installation requirements, ideal for Mining, Port, Construction, Prime power and back-up power
Learn More
Back-up Power
PowerLink offers a variety of products within the QSV Series to meet diverse application needs and installation requirements, ideal for Mining, Port, Construction, Prime power and back-up power
Learn MoreFAQs
How to choose your new power generation equipment?
Many customers need to consider the technical and economic feasibility of diesel power generation solutions. Usually the diesel genset is combined with the external large power grid, and the energy supply complements each other, which can improve the reliability and flexibility of the entire system.
To find a cost-effective, technically reliable and more environmentally friendly power generation solution, we recommend that you consider the following important factors when choosing a power generation equipment:
- The most important thing is the installation cost. Diesel genset solutions offer very competitive installation costs compared to other power generation systems, with a limited footprint for a single kilowatt project.
- Power generation efficiency. The power generation efficiency of diesel gensets directly affects the economy of the project. PowerLink diesel gensets are efficient and offer a high value.
- Manufacturing and commissioning time. PowerLink diesel gensets usually take 3 to 6 months from production time plus construction and commissioning time. Your cash on delivery time will be shorter if you have it in stock.
- Modular installation solution. Considering that the equipment is ultimately delivered safely to the installation site, the modular structure makes project installation easier and commissioning simpler and faster.
- Another very important factor in determining the choice of power generation equipment: the operating expenses associated with the equipment. These aspects need to be considered: service intervals, spare parts costs, downtime during maintenance, and the entire working cycle of the equipment before the overhaul. Based on our long experience, we offer multi-year service contracts for PowerLink gensets. This can help reduce the need for spare parts and can predict service times in advance, reducing operating costs throughout the engine’s working life.
- Help you select the most suitable equipment through the load analysis of the project. PowerLink’s wide range of diesel engines (5 to 3250KVA) will help you find the right solution for you.
- The surrounding environmental conditions will have an impact on the use of the equipment, thus affecting its actual power output capacity. In other words, in some cases, your power output may be much lower than the rated power. If you plan to operate equipment at high temperatures and/or altitudes significantly above sea level, be aware of this factor.
How is the genset noise reduced?
The following three methods are usually used for noise reduction:
- Exhaust noise reduction: exhaust noise is the main source of generator noise, and a special muffler is usually selected for noise reduction.
- Reducing axial fan noise.
- Sound insulation and noise reduction treatment of the machine room and genset vibration isolation.
What is the backpower? What are the two serious consequences?
The case of self-provided generator sending power to the municipal network is called reverse power supply. There are two kinds of serious consequences:
- The municipal power grid is not cut off, and the city network power supply and the self-provided generator power supply produce non-synchronous operation, which will destroy the unit. If the capacity of the self-provided generator is large, it will also cause the municipal power grid to shake.
- The city network has been outage is being tested, and its self-provided generator provides power backwards. It will electrocute some of the inspection staff.
What are the reasons why the water temperature is high and the alarm stops and cannot be used?
- Water tank leakage or insufficient water;
- The water temperature sensor is damaged.
- The water tank waterway dirt is too thick, or the heat sink oil is too much.
- Fan belt wear is too large, and there is insufficient pressure.
- Pump wear, pump water is insufficient.
- The thermostat opening Angle is not enough; there is a stuck phenomenon.
- The cylinder gasket is damaged, and the water channel is connected to the cylinder.
- The cylinder liner wears too much, and there is local water seepage.
- The ventilation of the equipment room does not meet the requirements.
- Engine overload operation;
- Excessive fuel supply (including engine weakness).
How is the genset used in coordination with the main power supply?
Stable commercial power is supplied to the power load through cables. When the main power supply is interrupted due to a power outage, a signal is sent from the transfer switch to the genset, and then the genset starts and sends the generated power to the load. When the main power supply is restored, the switch will cut off the power supply of the genset and restore it to the main power supply.