1250-3250kVA

HV Series

HV Series delivers 1250-3250 kVA, powered by reliable Mitsubishi engines, along with Cummins and Perkins options. Choose from voltage options of 3300V, 6300V, 10500V, or 13800V for 60Hz areas.

Designed by PowerLink, these generators simplify installation and maintenance, ensuring efficient and durable operation.

HV Series
HV Series
HV Series
Commited to Service

Maintainable Design
Easy maintenance with low operating
costs

Commited to Service

Quick Transport
Quick to move, simple installation

Commited to Service

Effortless Use
User-friendly with easy plug-and-play

Commited to Service

Reliable Power
Consistent power output in tough
Conditions

Features

Service-Friendly Design

Easy Maintenance & Low Operating Costs. Rapid Start-Up &  Excellent Load Surge

 

Reliable & Stable

Consistent Output in Tough Conditions. Stable Performance & Mature Technology

 

Kinematic Coupling Design

Ensures Long-Term Reliable & Safe Operation

 

Ask an Expert

PowerLink provides tailored, high-efficiency energy solutions for sustainable power around the world.

HV Series Parameter

HVC1275S
HVC1275S
HVC1275S
HVC1500S
HVC1500S
HVC1500S
HVC1600S
HVC1600S
HVC1600S
HVC1875S
HVC1875S
HVC1875S
HVC2045S
HVC2045S
HVC2045S
HVC2750S
HVC2750S
HVC2750S
HVC3360S
HVC3360S
HVC3360S
HVC1400S
HVC1400S
HVC1400S
HVC1540S
HVC1540S
HVC1540S
HVC1650S
HVC1650S
HVC1650S
HVC1829S
HVC1829S
HVC1829S
HVC2000S
HVC2000S
HVC2000S
HVC2750S
HVC2750S
HVC2750S
HVC3100S
HVC3100S
HVC3100S
HVM1290S
HVM1290S
HVM1290S
HVM1500S
HVM1500S
HVM1500S
HVM1728S
HVM1728S
HVM1728S
HVM2045S
HVM2045S
HVM2045S
HVP1250S
HVP1250S
HVP1250S
HVP1500S
HVP1500S
HVP1500S
HVP1710S
HVP1710S
HVP1710S
HVP1850S
HVP1850S
HVP1850S
HVP2000S
HVP2000S
HVP2000S
HVP2250S
HVP2250S
HVP2250S
HVC1275S

HVC1275S

Emission Standard Non \ \ \
Engine Model KTA50-G3 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 1275 kVA / 1020 kW \ \ \
ESP 1400 kVA / 1120 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1275S

HVC1275S

Emission Standard Non \ \ \
Engine Model KTA50-G3 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 1275 kVA / 1020 kW \ \ \
ESP 1400 kVA / 1120 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1275S

HVC1275S

Emission Standard Non \ \ \
Engine Model KTA50-G3 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 1275 kVA / 1020 kW \ \ \
ESP 1400 kVA / 1120 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1500S

HVC1500S

Emission Standard Non \ \ \
Engine Model KTA50-GS8 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 1500 kVA / 1200 kW \ \ \
ESP 1675 kVA / 1340 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1500S

HVC1500S

Emission Standard Non \ \ \
Engine Model KTA50-GS8 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 1500 kVA / 1200 kW \ \ \
ESP 1675 kVA / 1340 kW \ \ \

 

Specification

Warranty Manual

Brochure Manual

HVC1500S

HVC1500S

Emission Standard Non \ \ \
Engine Model KTA50-GS8 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 1500 kVA / 1200 kW \ \ \
ESP 1675 kVA / 1340 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1600S

HVC1600S

Emission Standard Non \ \ \
Engine Model QSK60-G12 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 1601 kVA / 1474 kW \ \ \
ESP 1843 kVA / 1601 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1600S

HVC1600S

Emission Standard Non \ \ \
Engine Model QSK60-G12 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 1601 kVA / 1474 kW \ \ \
ESP 1843 kVA / 1601 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1600S

HVC1600S

Emission Standard Non \ \ \
Engine Model QSK60-G12 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 1601 kVA / 1474 kW \ \ \
ESP 1843 kVA / 1601 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1875S

HVC1875S

Emission Standard Non \ \ \
Engine Model QSK60G3 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 1875 kVA / 1500 kW \ \ \
ESP 2063 kVA / 650 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1875S

HVC1875S

Emission Standard Non \ \ \
Engine Model QSK60G3 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 1875 kVA / 1500 kW \ \ \
ESP 2063 kVA / 650 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1875S

HVC1875S

Emission Standard Non \ \ \
Engine Model QSK60G3 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 1875 kVA / 1500 kW \ \ \
ESP 2063 kVA / 650 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2045S

HVC2045S

Emission Standard Non \ \ \
Engine Model QSK60G4 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP  2045 kVA / 1636 kW \ \ \
ESP  2250 kVA / 1800 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2045S

HVC2045S

Emission Standard Non \ \ \
Engine Model QSK60G4 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP  2045 kVA / 1636 kW \ \ \
ESP  2250 kVA / 1800 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2045S

HVC2045S

Emission Standard Non \ \ \
Engine Model QSK60G4 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 2045 kVA / 1636 kW \ \ \
ESP 2250 kVA / 1800 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2750S

HVC2750S

Emission Standard Non \ \ \
Engine Model QSK78-G9 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 2750 kVA / 2200 kW \ \ \
ESP 3000 kVA / 2400 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2750S

HVC2750S

Emission Standard Non \ \ \
Engine Model QSK78-G9 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 2750 kVA / 2200 kW \ \ \
ESP 3000 kVA / 2400 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2750S

HVC2750S

Emission Standard Non \ \ \
Engine Model QSK78-G9 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 2750 kVA / 2200 kW \ \ \
ESP 3000 kVA / 2400 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC3360S

HVC3360S

Emission Standard Non \ \ \
Engine Model QSK95-G4 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 3362 kVA / 2690 kW \ \ \
ESP 3762 kVA / 3010 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC3360S

HVC3360S

Emission Standard Non \ \ \
Engine Model QSK95-G4 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 3362 kVA / 2690 kW \ \ \
ESP 3762 kVA / 3010 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC3360S

HVC3360S

Emission Standard Non \ \ \
Engine Model QSK95-G4 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 3362 kVA / 2690 kW \ \ \
ESP 3762 kVA / 3010 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1400S

HVC1400S

Emission Standard Tire2 \ \ \
Engine Model QSK50-G3 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 1400 kVA / 1120 kW \ \ \
ESP 1540 kVA / 1232 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1400S

HVC1400S

Emission Standard Tire2 \ \ \
Engine Model QSK50-G3 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 1400 kVA / 1120 kW \ \ \
ESP 1540 kVA / 1232 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1400S

HVC1400S

Emission Standard Tire2 \ \ \
Engine Model QSK50-G3 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 1400 kVA / 1120 kW \ \ \
ESP 1540 kVA / 1232 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1540S

HVC1540S

Emission Standard Tire2 \ \ \
Engine Model QSK50-G4 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 1540 kVA / 1232 kW \ \ \
ESP 1700 kVA / 1360 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1540S

HVC1540S

Emission Standard Tire2 \ \ \
Engine Model QSK50-G4 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 1540 kVA / 1232 kW \ \ \
ESP 1700 kVA / 1360 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1540S

HVC1540S

Emission Standard Tire2 \ \ \
Engine Model QSK50-G4 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 1540 kVA / 1232 kW \ \ \
ESP 1700 kVA / 1360 kW \ \ \

 

Specification

Warranty Manual

Brochure Manual

HVC1650S

HVC1650S

Emission Standard Tire2 \ \ \
Engine Model QSK50-G7 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 1650 kVA / 1320 kW \ \ \
ESP 1825 kVA / 1460 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1650S

HVC1650S

Emission Standard Tire2 \ \ \
Engine Model QSK50-G7 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 1650 kVA / 1320 kW \ \ \
ESP 1825 kVA / 1460 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1650S

HVC1650S

Emission Standard Tire2 \ \ \
Engine Model QSK50-G7 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 1650 kVA / 1320 kW \ \ \
ESP 1825 kVA / 1460 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1829S

HVC1829S

Emission Standard Tire2 \ \ \
Engine Model QSK60-G12 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 1829 kVA / 1463  kW \ \ \
ESP 2008 kVA / 1606 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1829S

HVC1829S

Emission Standard Tire2 \ \ \
Engine Model QSK60-G12 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 1829 kVA / 1463  kW \ \ \
ESP 2008 kVA / 1606 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC1829S

HVC1829S

Emission Standard Tire2 \ \ \
Engine Model QSK60-G12 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 1829 kVA / 1463  kW \ \ \
ESP 2008 kVA / 1606 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2000S

HVC2000S

Emission Standard Tire2 \ \ \
Engine Model QSK60-G13 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 2003 kVA / 1602 kW \ \ \
ESP 2254 kVA / 1803 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2000S

HVC2000S

Emission Standard Tire2 \ \ \
Engine Model QSK60-G13 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 2003 kVA / 1602 kW \ \ \
ESP 2254 kVA / 1803 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2000S

HVC2000S

Emission Standard Tire2 \ \ \
Engine Model QSK60-G13 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 2003 kVA / 1602 kW \ \ \
ESP 2254 kVA / 1803 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2750S

HVC2750S

Emission Standard Tire2 \ \ \
Engine Model QSK78-G15 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 2750 kVA / 2200 kW \ \ \
ESP 3000 kVA / 2400 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC2750S

HVC2750S

Emission Standard Tire2 \ \ \
Engine Model QSK78-G15 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 2750 kVA / 2200 kW \ \ \
ESP 3000 kVA / 2400 kW \ \ \

 

Specification

Warranty Manual

Brochure Manual

HVC2750S

HVC2750S

Emission Standard Tire2 \ \ \
Engine Model QSK78-G15 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 2750 kVA / 2200 kW \ \ \
ESP 3000 kVA / 2400 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC3100S

HVC3100S

Emission Standard Tire2 \ \ \
Engine Model QSK95-G5 \ \ \
Engine Brand Cummins \ \ \
Voltage 3300V \ \ \
PRP 3126 kVA / 2500 kW \ \ \
ESP 3500 kVA / 2800 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC3100S

HVC3100S

Emission Standard Tire2 \ \ \
Engine Model QSK95-G5 \ \ \
Engine Brand Cummins \ \ \
Voltage 6300V \ \ \
PRP 3126 kVA / 2500 kW \ \ \
ESP 3500 kVA / 2800 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVC3100S

HVC3100S

Emission Standard Tire2 \ \ \
Engine Model QSK95-G5 \ \ \
Engine Brand Cummins \ \ \
Voltage 10500V \ \ \
PRP 3126 kVA / 2500 kW \ \ \
ESP 3500 kVA / 2800 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVM1290S

HVM1290S

Emission Standard Non \ \ \
Engine Model S12R-PTA-C \ \ \
Engine Brand  MITSUBISHI \ \ \
Voltage 3300V \ \ \
PRP 1290 kVA / 1032 kW \ \ \
ESP  1425 kVA / 1140 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVM1290S

HVM1290S

Emission Standard Non \ \ \
Engine Model S12R-PTA-C \ \ \
Engine Brand  MITSUBISHI \ \ \
Voltage 6300V \ \ \
PRP 1290 kVA / 1032 kW \ \ \
ESP  1425 kVA / 1140 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVM1290S

HVM1290S

Emission Standard Non \ \ \
Engine Model S12R-PTA-C \ \ \
Engine Brand  MITSUBISHI \ \ \
Voltage 10500V \ \ \
PRP 1290 kVA / 1032 kW \ \ \
ESP  1425 kVA / 1140 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVM1500S

HVM1500S

Emission Standard Non \ \ \
Engine Model S12R-PTAA2-C \ \ \
Engine Brand MITSUBISHI \ \ \
Voltage 3300V \ \ \
PRP 1500 kVA / 1200 kW \ \ \
ESP 1650 kVA / 1320 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVM1500S

HVM1500S

Emission Standard Non \ \ \
Engine Model  S12R-PTAA2-C \ \ \
Engine Brand  MITSUBISHI \ \ \
Voltage 6300V \ \ \
PRP 1500 kVA / 1200 kW \ \ \
ESP 1650 kVA / 1320 kW \ \ \

 

Specification

Warranty Manual

Brochure Manual

HVM1500S

HVM1500S

Emission Standard Non \ \ \
Engine Model S12R-PTAA2-C \ \ \
Engine Brand MITSUBISHI \ \ \
Voltage 10500V \ \ \
PRP 1500 kVA / 1200 kW \ \ \
ESP 1650 kVA / 1320 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVM1728S

HVM1728S

Emission Standard Non \ \ \
Engine Model S16R-PTA-C \ \ \
Engine Brand  MITSUBISHI \ \ \
Voltage 3300V \ \ \
PRP 1728 kVA / 1382 kW \ \ \
ESP 1900 kVA / 1520 kW \ \ \

 

Specification

Warranty Manual

Brochure Manual

HVM1728S

HVM1728S

Emission Standard Non \ \ \
Engine Model S16R-PTA-C \ \ \
Engine Brand MITSUBISHI \ \ \
Voltage 6300V \ \ \
PRP 1728 kVA / 1382 kW \ \ \
ESP 1900 kVA / 1520 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVM1728S

HVM1728S

Emission Standard Non \ \ \
Engine Model S16R-PTA-C \ \ \
Engine Brand MITSUBISHI \ \ \
Voltage 10500V \ \ \
PRP 1728 kVA / 1382 kW \ \ \
ESP 1900 kVA / 1520 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVM2045S

HVM2045S

Emission Standard Non \ \ \
Engine Model  S16R-PTAA2-C \ \ \
Engine Brand  MITSUBISHI \ \ \
Voltage 3300V \ \ \
PRP 2045 kVA / 1636 kW \ \ \
ESP 2250 kVA / 1800 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVM2045S

HVM2045S

Emission Standard Non \ \ \
Engine Model  S16R-PTAA2-C \ \ \
Engine Brand  MITSUBISHI \ \ \
Voltage 6300V \ \ \
PRP 2045 kVA / 1636 kW \ \ \
ESP 2250 kVA / 1800 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVM2045S

HVM2045S

Emission Standard Non \ \ \
Engine Model S16R-PTAA2-C \ \ \
Engine Brand MITSUBISHI \ \ \
Voltage 10500V \ \ \
PRP 2045 kVA / 1636 kW \ \ \
ESP 2250 kVA / 1800 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP1250S

HVP1250S

Emission Standard Non \ \ \
Engine Model 4012-46TWG2A \ \ \
Engine Brand Perkins \ \ \
Voltage 3300V \ \ \
PRP 1250 kVA / 1000 kW \ \ \
ESP 1375 kVA / 1100 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP1250S

HVP1250S

Emission Standard Non \ \ \
Engine Model 4012-46TWG2A \ \ \
Engine Brand Perkins \ \ \
Voltage 6300V \ \ \
PRP 1250 kVA / 1000 kW \ \ \
ESP 1375 kVA / 1100 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP1250S

HVP1250S

Emission Standard Non \ \ \
Engine Model 4012-46TWG2A \ \ \
Engine Brand Perkins \ \ \
Voltage 10500V \ \ \
PRP 1250 kVA / 1000 kW \ \ \
ESP 1375 kVA / 1100 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP1500S

HVP1500S

Emission Standard Non \ \ \
Engine Model 4012-46TAG2A \ \ \
Engine Brand Perkins \ \ \
Voltage 3300V \ \ \
PRP 1500 kVA / 1200 kW \ \ \
ESP 1650 kVA / 1320 kW \ \ \

 

Specification

Warranty Manual

Brochure Manual

HVP1500S

HVP1500S

Emission Standard Non \ \ \
Engine Model 4012-46TAG2A \ \ \
Engine Brand Perkins \ \ \
Voltage 6300V \ \ \
PRP 1500 kVA / 1200 kW \ \ \
ESP 1650 kVA / 1320 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP1500S

HVP1500S

Emission Standard Non \ \ \
Engine Model 4012-46TAG2A \ \ \
Engine Brand Perkins \ \ \
Voltage 10500V \ \ \
PRP 1500 kVA / 1200 kW \ \ \
ESP 1650 kVA / 1320 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP1710S

HVP1710S

Emission Standard Non \ \ \
Engine Model 4012-46TAG3A \ \ \
Engine Brand Perkins \ \ \
Voltage 3300V \ \ \
PRP 1710 kVA / 1368 kW \ \ \
ESP 1881 kVA / 1505 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP1710S

HVP1710S

Emission Standard Non \ \ \
Engine Model 4012-46TAG3A \ \ \
Engine Brand Perkins \ \ \
Voltage 6300V \ \ \
PRP 1710 kVA / 1368 kW \ \ \
ESP 1881 kVA / 1505 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP1710S

HVP1710S

Emission Standard Non \ \ \
Engine Model 4012-46TAG3A \ \ \
Engine Brand Perkins \ \ \
Voltage 10500V \ \ \
PRP 1710 kVA / 1368 kW \ \ \
ESP 1881 kVA / 1505 kW \ \ \

 

Specification

Warranty Manual

Brochure Manual

HVP1850S

HVP1850S

Emission Standard Non \ \ \
Engine Model 4016-61TRG1 \ \ \
Engine Brand Perkins \ \ \
Voltage 3300V \ \ \
PRP 1850 kVA / 1480 kW \ \ \
ESP 2035 kVA / 1628 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP1850S

HVP1850S

Emission Standard Non \ \ \
Engine Model 4016-61TRG1 \ \ \
Engine Brand Perkins \ \ \
Voltage 6300V \ \ \
PRP 1850 kVA / 1480 kW \ \ \
ESP 2035 kVA / 1628 kW \ \ \

 

Specification

Warranty Manual

Brochure Manual

HVP1850S

HVP1850S

Emission Standard Non \ \ \
Engine Model 4016-61TRG1 \ \ \
Engine Brand Perkins \ \ \
Voltage 10500V \ \ \
PRP 1850 kVA / 1480 kW \ \ \
ESP 2035 kVA / 1628 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP2000S

HVP2000S

Emission Standard Non \ \ \
Engine Model 4016-61TRG2 \ \ \
Engine Brand Perkins \ \ \
Voltage 3300V \ \ \
PRP 2000 kVA / 1600 kW \ \ \
ESP 2200 kVA / 1760 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP2000S

HVP2000S

Emission Standard Non \ \ \
Engine Model 4016-61TRG2 \ \ \
Engine Brand Perkins \ \ \
Voltage 10500V \ \ \
PRP 2000 kVA / 1600 kW \ \ \
ESP 2200 kVA / 1760 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP2000S

HVP2000S

Engine Model VR4-4.8TAG3 \ \ \
Engine Brand POWERLINK \ \ \
Voltage 380V 400V 415V 440V
PRP 125 kVA / 100 kW \ \ \
ESP 138 kVA / 100 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP2250S

HVP2250S

Emission Standard Non \ \ \
Engine Model 4016-61TRG3 \ \ \
Engine Brand Perkins \ \ \
Voltage 3300V \ \ \
PRP 2250 kVA / 1800 kW \ \ \
ESP 2500 kVA / 2000 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP2250S

HVP2250S

Emission Standard Non \ \ \
Engine Model 4016-61TRG3 \ \ \
Engine Brand Perkins \ \ \
Voltage 6300V \ \ \
PRP 2250 kVA / 1800 kW \ \ \
ESP 2500 kVA / 2000 kW \ \ \

Specification

Warranty Manual

Brochure Manual

HVP2250S

HVP2250S

Emission Standard Non \ \ \
Engine Model 4016-61TRG3 \ \ \
Engine Brand Perkins \ \ \
Voltage 10500V \ \ \
PRP 2250 kVA / 1800 kW \ \ \
ESP 2500 kVA / 2000 kW \ \ \

Specification

Warranty Manual

Brochure Manual

Video

HV Series video

Applications

  • Mining
  • Port
  • Construction
  • Back-up Power
Mining

Mining

PowerLink’s HV Series features a flexible product lineup that aligns with diverse application and installation needs—ideal across Mining, Ports, Construction, prime and backup power.

Learn More
Port

Port

The HV Series from PowerLink offers a diverse product portfolio, catering to broad application/installation requirements—perfect for Mining, Ports, Construction, plus primary and standby power.

Learn More
Construction

Construction

PowerLink’s Multi-fit HV Series fits diverse application & installation needs—suited for Mining, Ports, Construction, prime/standby power.

Learn More
Back-up Power

Back-up Power

PowerLink’s HV Series delivers tailored power solutions, engineered to suit varied application and installation demands—reliable for Mining, Ports, Construction, prime and backup power use cases.

Learn More

FAQs

If three sets of generator sets are equipped to supply power to the terminal, and the grid is not connected to the Internet mode, if the power grid is cut off, the generator set starts, at this time how much electricity the generator set needs to generate is controlled by what? Is it controlled by an electrical terminal?

These are two questions. Connected to the Internet and no external network, the working mode of the unit is not the same. When there is an external network, the grid is not connected to the Internet, most of the unit adopts the power output method, and the user’s power management center determines how much electricity the unit generates. When there is no external network, most units follow the load, and the load determines how much electricity the unit generates.

Warranty period

Please request the warranty manual document from the agent, which contains detailed explanations of the warranty policy.

Unit grounding lightning protection problem

Grounding bolts are installed on the chassis of the unit. Customers can connect their own grounding network to the grounding bolts. The lightning arrester is optional equipment.

What are the reasons why the water temperature is high and the alarm stops and cannot be used?

  • Water tank leakage or insufficient water;
  • The water temperature sensor is damaged.
  • The water tank waterway dirt is too thick, or the heat sink oil is too much.
  • Fan belt wear is too large, and there is insufficient pressure.
  • Pump wear, pump water is insufficient.
  • The thermostat opening Angle is not enough; there is a stuck phenomenon.
  • The cylinder gasket is damaged, and the water channel is connected to the cylinder.
  • The cylinder liner wears too much, and there is local water seepage.
  • The ventilation of the equipment room does not meet the requirements.
  • Engine overload operation;
  • Excessive fuel supply (including engine weakness).

Ultra-low temperature operation of diesel gensets

Diesel generator sets require preheaters such as water jacket preheaters, fuel oil preheaters, battery heaters, and space heaters to operate at ultra-low temperatures (such as below minus 10°C).

All products provided by our company are energy products
Welcome to contact us