4.16KV | 10.5KV | 11KV | 13.8KV

Datacenter Generators

PowerLink 4.16kV‑13.8kV high‑power generator sets are built for mission‑critical hyperscale AI data‑centres, offering 2500kW‑3750kW power output at 4.16kV/10.5kV/11kV/13.8kV.
Medium‑voltage transmission reduces cable costs and power losses over large‑area sites. Containerised solutions with PLC‑500 controllers support smooth multi‑unit parallel‑synchronisation for N+1 / 2N redundancy.

Fully load‑tested and custom‑matched to local switchgear, they deliver fail‑safe backup power for high‑availability AI computing infrastructure.

Commited to Service


Pre‑Built Containers

Commited to Service


24/7 Backup

Commited to Service


Paralleled Resilience

Commited to Service


Dual‑frequency flexibility

Features

Medium‑Voltage Power Output

2500kW‑3750kW, multi‑voltage ratings (4.16kV‑13.8kV), tailored for hyperscale AI data centres.

Lower Cabling & Energy Loss Costs

Minimises transmission losses and heavy‑duty cable investment for large campus deployments.

Stable Multi‑Unit Parallel Operation

PLC‑500 controller enables seamless genset synchronisation to build N+1 / 2N redundant power systems.

Mission‑Critical‑Grade Reliability

With strict load testing, delivering uninterrupted backup for high‑availability AI infrastructure.

Ask an Expert

PowerLink provides tailored, high-efficiency energy solutions for sustainable power around the world.

Datacenter Genset Parameter

1600KW
1800KW
2000KW
2400KW
2500KW
2700KW
3000KW
3200KW
3600KW
STS6500 dual axis solar tracker parameter table
60HZ

1600KW

PRP/DCP 1600KW 2000KVA
Emission Standard EPA
Compliance with Standards UL
Voltage 4.16KV 13.8KV
Noise Level @ 75% Load 87
Fuel Tank Capacity 2400L

Specification

Warranty Manual

STS6500 dual axis solar tracker parameter table
60HZ

1800KW

PRP/DCP 1800KW 2250KVA
Emission Standard EPA
Compliance with Standards UL
Voltage 4.16KV 13.8KV
Noise Level @ 75% Load 87
Fuel Tank Capacity 2400L

Specification

Warranty Manual

STS6500 dual axis solar tracker parameter table
50HZ

2000KW

PRP/DCP 2000KW 2500KVA
Emission Standard Non
Compliance with Standards CE
Voltage 10.5KV 11KV
Noise Level @ 75% Load 87
Fuel Tank Capacity 2400L

Specification

Warranty Manual

STS6500 dual axis solar tracker parameter table
50HZ

2400KW

PRP/DCP 2400KW 3000KVA
Emission Standard Non
Compliance with Standards CE
Voltage 10.5KV 11KV
Noise Level @ 75% Load 87
Fuel Tank Capacity 2400L

Specification

Warranty Manual

STS6500 dual axis solar tracker parameter table
50HZ

2500KW

PRP/DCP 2500KW 3125KVA
Emission Standard Non
Compliance with Standards CE
Voltage 10.5KV 11KV
Noise Level @ 75% Load 87
Fuel Tank Capacity 2400L

Specification

Warranty Manual

STS6500 dual axis solar tracker parameter table
50HZ

2700KW

PRP/DCP 2700KW 3375KVA
Emission Standard Non
Compliance with Standards CE
Voltage 10.5KV 11KV
Noise Level @ 75% Load 87
Fuel Tank Capacity 2400L

Specification

Warranty Manual

STS6500 dual axis solar tracker parameter table
50HZ

3000KW

PRP/DCP 3000KW 3750KVA
Emission Standard Non
Compliance with Standards CE
Voltage 10.5KV 11KV
Noise Level @ 75% Load 87
Fuel Tank Capacity 2400L

Specification

Warranty Manual

STS6500 dual axis solar tracker parameter table
60HZ

3200KW

PRP/DCP 3200KW 4000KVA
Emission Standard EPA
Compliance with Standards UL
Voltage 4.16KV 13.8KV
Noise Level @ 75% Load 87
Fuel Tank Capacity 2400L

Specification

Warranty Manual

STS6500 dual axis solar tracker parameter table
60HZ

3600KW

PRP/DCP 3600KW 4500KVA
Emission Standard EPA
Compliance with Standards UL
Voltage 4.16KV 13.8KV
Noise Level @ 75% Load 87
Fuel Tank Capacity 2400L

Specification

Warranty Manual

Case

PowerLink 2000kW COP Modular PowerPod Solution for Data Center

PowerLink 2000kW COP Modular PowerPod Solution for Data Center

  • Equipment: 2500KVA intelligent container genset
  • Scheme: Double-layer staggered stacking backup power system
  • Field: High-reliability power guarantee for Tier III/IV AIDC
  • Power Range: 2000kW single unit, scalable MW-level cluster
Learn More
100KVA Huawei datacenter Standby Power

100KVA Huawei datacenter Standby Power

  • Location: Indonesia
  • Equipment: 2*WPS50S
  • Electric output mode: Prime Supply
  • Field / fuel: Datacenter / Diesel
  • Total output power: 100KVA
Learn More

FAQs

How to determine generator‑set capacity?

Sizing for data‑centre gensets shall consider these factors:
  1. Total IT load: Aggregated power draw of servers, storage and networking hardware.
  2. PUE requirements: Power‑Usage‑Effectiveness determines power demand for non‑IT loads such as cooling and lighting.
  3. N+1 redundancy: Data centres commonly adopt N+1 or 2N redundancy so that remaining units can carry full load if one unit fails.
  4. Future expansion: Reserve 20%‑30% capacity margin.
  5. Parallel‑operation considerations: When multiple gensets run in parallel, avoid excessively large single‑unit ratings to prevent excessive power shortfall upon single‑unit failure.

What are the differences between 400V~480V and 4.16KV~13.8KV generator sets? How to select?

Selection advice: For small‑to‑medium data centres (single‑unit capacity ≤3000kW), 400V~480V units are preferred for direct integration with existing low‑voltage distribution. For large data centres (single‑unit capacity ≥3000kW) with high‑voltage infrastructure, 4.16KV~13.8KV units are recommended to reduce transmission loss and cable costs.

What is the difference between PRP and DCP?

  • PRP (Prime Power Rating): The maximum power the genset can deliver continuously under standard operating conditions, with a 10% overload capability, for applications requiring prime‑power supply.
  • DCP (Data Center Power): A power rating defined specifically for data‑centre operation; it represents the recommended continuous operating power for data‑centre loads.
In selection, regular operating load of the data centre shall not exceed the DCP rating. PRP may be referenced for short‑term overload conditions.